300L bentonite slurry mixer
Leadcrete’s LM300E is publicly listed as a 300L colloidal mixer with a built-in impeller pump for compatible grout materials, including bentonite. Its published water-measured output should be distinguished from slurry production capacity. Selection requires checking the formulation, transfer conditions and whether separate agitation or injection equipment is needed.
300L bentonite slurry mixer
A 300L bentonite slurry mixer must be selected for both slurry preparation and the operation that follows mixing. A machine may incorporate a pump for mixing and discharge, but that does not automatically establish its ability to deliver bentonite slurry through a specified pipeline or perform pressure grouting.
Leadcrete’s LM300E provides a documented starting point for this assessment. Its published specifications identify a 300L colloidal mixer with a built-in impeller pump. Understanding what each parameter describes helps buyers distinguish the mixing duty from transfer and injection requirements.
Read the published specifications by function
Leadcrete lists the LM300E as a high shear grout mixer for compatible materials that can include cement, bentonite and sand. The published technical data include:
| Published item | LM300E specification | Meaning for equipment selection |
|---|---|---|
| Capacity | 300L | Confirm the permitted working charge for the intended formulation. |
| Output | 1,000L/min, measured with water | Does not establish bentonite slurry production or delivery at a specified pressure. |
| Impeller speed | 1,450rpm | Describes the rotating component, rather than an independently verified slurry result. |
| Power | 7.5kW | Check the proposed drive and actual site electrical supply. |
| Voltage | Three-phase, 380V, 50Hz | Confirm compatibility before ordering. |
These are published model specifications, not performance confirmed for a particular bentonite formulation or order. The appropriate operating conditions must be established for the proposed application.

Water-tested flow is different from finished slurry output
The published 1,000L/min figure is explicitly qualified as measured with water. It should not be presented as the quantity of finished bentonite slurry that the equipment can prepare every minute.
A bentonite slurry mixer must complete water charging, powder incorporation, mixing and discharge. The preparation rate depends on that complete sequence, while the discharge rate also depends on the slurry and connected pipeline.
The water-measured figure should therefore not be multiplied into an hourly slurry production claim. It also lacks the pressure and test conditions needed to establish a delivery duty.
When comparing bentonite mixing equipment, request separate information for usable batch volume, complete preparation cycle and transfer performance with the intended slurry. Keeping these figures separate prevents a large flow number from masking an unsuitable operating arrangement.
Define where the mixed slurry must go
A colloidal bentonite mixer uses intensive mixing to disperse material. Its discharge arrangement then needs to move the prepared batch to the next stage, which might be a nearby tank, a pump hopper or another receiving vessel.
Describe that route before deciding whether the built-in pump is sufficient. Required information includes pipe diameter, horizontal distance, elevation difference and the condition of the slurry when transferred.
For a bentonite grout mixer and pump enquiry involving injection, the required flow and pressure must be assessed together. The LM300E’s published water-flow figure does not establish injection pressure or demonstrate that the same flow is available against pipeline resistance.
A separate grout pump may be required where the downstream duty exceeds the confirmed discharge capability. Its selection should follow the approved project requirements rather than an assumed relationship between mixer capacity and injection pressure.
Choose the supporting equipment around withdrawal demand
A single mixer may suit batch preparation where the receiving process can accommodate interruptions between discharges. If slurry must remain available while another batch is prepared, a bentonite mixer and agitator arrangement may be more appropriate.
The agitator provides a holding stage between preparation and withdrawal. Its usable volume and operating arrangement must match the downstream demand; adding a tank alone does not prove continuous supply.
For a bentonite slurry mixing system connected to an existing plant, identify which components are already available. A project with suitable storage and pumping equipment may need only a mixer and transfer connection. Another project may require the complete preparation, holding and delivery arrangement.
Leadcrete’s LM300E product information describes use with other mixing and pumping equipment and identifies an agitator combination as an available arrangement. The final supply scope should specify which components and connections are included.

Verify the proposed duty with representative slurry
A useful equipment assessment uses the specified bentonite grade, concentration and make-up water. These conditions determine whether published information is relevant to the intended work.
Where transfer performance needs verification, record the pipeline arrangement and the slurry condition during discharge. A demonstration into an adjacent open container does not establish delivery through a longer or elevated line.
Agree on the acceptance requirements before testing. Depending on the application, these may cover dispersion, fluid properties, discharge performance and compatibility with the next operation. A successful trial supports the conditions tested rather than every formulation the mixer might process.
For a Leadcrete quotation, provide the material specification, required preparation rate, transfer route, downstream flow and pressure requirements, and available power supply.

Contact sales@leadcrete.com to discuss a 300L mixing arrangement based on your actual slurry preparation and delivery duty.