Lightweight Foam Concrete Station Floor Heating System
Lightweight Foam Concrete Station Floor Heating System achieves efficient and uniform heating by embedding floor heating pipes in the ground structure and using lightweight foam concrete as the insulation layer and leveling layer. The following is an analysis of the technical principles, system advantages, application scenarios and design points.
Lightweight foam concrete station floor heating system is a production base for high-performance lightweight foam concrete (LFC) materials and related supporting products for floor heating engineering needs.


Technical features of lightweight foam concrete station floor heating system:
1. Material performance: Lightweight and high strength: dry density as low as 300 kg/m³, compressive strength up to 15 MPa, meeting the load-bearing requirements of floor heating systems.
2. Thermal insulation: Thermal conductivity is more than 50% lower than that of traditional materials, reducing heat loss.
Durability: anti-freeze and thaw, anti-corrosion, service life of more than 50 years.
3. Production process: Physical foaming technology: the foaming agent is mixed with cement slurry through high-pressure air to form a uniform closed-cell structure.
Automated control: The PLC system is used to monitor parameters such as density and strength in real time to ensure stable product quality.
4. Construction advantages: Good fluidity: can be pumped to complex structural parts and adapted to large-scale construction.
Rapid hardening: 24-hour strength reaches 70% of the design value, shortening the construction period by 30%-50%.


Application advantages of lightweight foam concrete station floor heating system:
1. Energy saving and high efficiency: The thermal efficiency of the floor heating system is increased by 20%-30%, reducing operating costs.
Low-temperature heating (40-60℃) reduces heat source energy consumption and meets green building standards.
2. Space optimization: The insulation layer and the leveling layer are integrated, saving 5-10 cm of floor height and releasing headroom.
3. Environmental protection and noise reduction: The material is non-toxic and harmless, and there is no dust pollution during construction.
The sound absorption coefficient reaches 0.15-0.25, reducing indoor noise.
4. Low maintenance cost: Strong crack resistance reduces later maintenance costs.



Typical cases of lightweight foam concrete station floor heating system:
1. Maoxian Station of Sichuan-Qinghai Railway
Adopting LFC floor heating system, the heating temperature is 45℃, the indoor temperature is stable at 20-22℃, the energy saving rate is 35%, and the construction period is shortened by 40%.
2. Beijing Daxing International Airport
Some areas use LFC floor heating, combined with ground source heat pumps, to achieve low-carbon heating and reduce carbon emissions by more than 20%.


The lightweight foam concrete floor heating system factory has become an important development direction of the floor heating industry through customized production, efficient construction and environmental protection and energy saving characteristics. If you have similar needs, please contact us directly, email: sales1@leadcrete.com